Upgrade your Amatrol Electric Motors Training!
Amatrol offers many upgrades to the Electric Motors Training System (85-MT2) to expand your teaching capabilities.
DC Generators Learning System
Amatrol’s DC Generators Learning System (85-MT2B) teaches industry-relevant DC generator skills including how to: operate, install, analyze performance, and select generators for various applications. A generator is a device that creates DC electricity and can be found in diesel locomotives, as well as aircraft and marine systems. The 85-MT2B requires the Electric Machines Learning System (85-MT2) and electricity (208 VAC/60 Hz/3 phase).
Alternators/Synchronous Motors Learning System
Amatrol’s Alternators / Synchronous Motors Learning System (85-MT2C) adds to the Electric Machines Learning System (85-MT2) to teach alternators and synchronous motors commonly found in industrial applications. Alternators provide a mobile source of AC electrical power while synchronous motors reduce power costs by correcting the overall power factor in a plant. Learners study industry-relevant skills including how to operate, install, and analyze the performance of alternators and synchronous motors.
Wound Rotor Motor Learning System
Amatrol’s Wound Rotor Motor Learning System (85-MT2D) covers the function, operation, and performance characteristics of wound rotor motors. While VFDs and standard induction motors have replaced wound rotor motors in many applications, these motors are still used for heavy-duty, high torque applications such as industrial cranes and hoists. The 85-MT2D requires the Basic Electric Machines Learning System (85-MT2) and the DC Generators Learning System (85-MT2B) for use.
Electric Motor Troubleshooting Learning System
The Motor Troubleshooting Learning System (85-MT2E), used in conjunction with the Basic Electrical Machines Learning System (85-MT2), covers the testing and troubleshooting of AC and DC motors using a multimeter and a megger meter. The skills and knowledge covered by this learning system will prove invaluable for industrial maintenance technicians or anyone working in a field that uses AC and/or DC motors. This system covers major topics like AC and DC motor failures, common methods of diagnosing these failures by using a multimeter and megger meter, and troubleshooting these failures.
Learn more about the upgrades available!
Please fill out this form to request a quote or to get more information the upgrades available for your electric motors training program.
DC Generators Learning System (85-MT2B)
Amatrol’s DC Generators Learning System (85-MT2B) teaches industry-relevant DC generator skills including how to: operate, install, analyze performance, and select generators for various applications. A generator is a device that creates DC electricity and can be found in diesel locomotives, as well as aircraft and marine systems. The 85-MT2B requires the Electric Machines Learning System (85-MT2) and electricity (208 VAC/60 Hz/3 phase).
The 85-MT2B includes resistive load and inductive load units that connect to the DC generator supplied with the 85-MT2 System to provide operation under various types of loads. Learners will use these components to study topics such as DC series generators, DC shunt generators, and DC compound generators. Amatrol learning systems feature a perfect combination of theoretical knowledge and hands-on skill building to reinforce each in a learner’s mind and strengthen comprehension for more advanced skills.
Learning Topics
- Performance Measurement
- Performance Analysis
- DC Series Generators
- DC Shunt Generators
- DC Compound Generators
- Installation
- Operation
Alternator / Synchronous Motor Learning System (85-MT2C)
Amatrol’s Alternators / Synchronous Motors Learning System (85-MT2C) adds to the Electric Machines Learning System (85-MT2) to teach alternators and synchronous motors commonly found in industrial applications. Alternators provide a mobile source of AC electrical power while synchronous motors reduce power costs by correcting the overall power factor in a plant. Learners study industry-relevant skills including how to operate, install, and analyze the performance of alternators and synchronous motors.
The 85-MT2C includes capacitive load, combination synchronous motor/ alternator, and synchronizing lights / switch unit. The capacitive load unit combines with the 85-MT2 to provide operation under various types of loads. In addition to industrial components, the 85-MT5C includes in-depth curriculum, instructor’s guide, and student reference guide. The curriculum covers major topical areas such as alternator output voltage and frequency, three dark synchronization method, and reversing a synchronous motor. This system also offers curriculum in an optional, highly interactive multimedia format.
Learning Topics
- Operation
- Installation
- Reversing Synchronous Motors
- Field Excitation
- Synchronizing Alternators
- Power Factor Correction
- Synchronous Motors
- Alternators
- Performance Analysis
- Performance Measurement
Wound Rotor Motor Learning System (85-MT2D)
Amatrol’s Wound Rotor Motor Learning System (85-MT2D) covers the function, operation, and performance characteristics of wound rotor motors. While VFDs and standard induction motors have replaced wound rotor motors in many applications, these motors are still used for heavy-duty, high torque applications such as industrial cranes and hoists. The 85-MT2D requires the Basic Electric Machines Learning System (85-MT2) and the DC Generators Learning System (85-MT2B) for use.
The 85-MT2D includes a wound rotor speed controller, a wound rotor motor, banana leads, in-depth curriculum, an installation guide, and a student reference guide. These components will be used to study topics such as wound rotor speed control, performance characteristics, and motor reversing. Amatrol learning systems feature real-world, industrial-grade components for both durability and to facilitate learners in gaining hands-on practice with actual equipment that they’ll find in the field.
Learning Topics
- Performance Measurement
- Performance Analysis
- Speed Controllers
- Motor Reversing
- Installation
- Operation
Electric Motor Troubleshooting Learning System (85-MT2E)
The Motor Troubleshooting Learning System (85-MT2E), used in conjunction with the Basic Electrical Machines Learning System (85-MT2), covers the testing and troubleshooting of AC and DC motors using a multimeter and a megger meter. The skills and knowledge covered by this learning system will prove invaluable for industrial maintenance technicians or anyone working in a field that uses AC and/or DC motors. This system covers major topics like AC and DC motor failures, common methods of diagnosing these failures by using a multimeter and megger meter, and troubleshooting these failures.
The 85-MT2E includes a motor connection box to practice hands-on skills such as troubleshooting faults in a DC motor and AC single-phase and three-phase motors, evaluating DC electric motor commutator and brush health, and using a multimeter to test an AC motor start/run capacitor. Amatrol’s learning systems feature real-world, industry-grade components for durability that will stand up to frequent use and to allow learners to gain real-world competencies. This learning system requires the 85-MT2, a digital multimeter, and a megger meter.
Learning Topics
- Performance Measurement
- Performance Analysis
- Speed Controllers
- Motor Reversing
- Installation
- Operation



